描述
Standardization
ISO 5599-1
Frame size
ISO 1
Actuating control
single solenoid
Return type
With spring return
Switching principle
5/2
Version
Spool valve, positive overlapping
Housing
Polyamide,Aluminum
Sealing material
Acrylonitrile butadiene rubber
UL (Underwriters Laboratories)
Protection class
IP65
Port size
EN 175301-803, form A
Type
Plug
Nominal flow Qn
1060 l/min
Compressed air connection input
Base plate DIN ISO 5599 size 1
Compressed air connection output
Base plate DIN ISO 5599 size 1
DC operating voltage
24 V
Version
Spool valve, positive overlapping
Sealing principle
Soft sealing
Blocking principle
Single base plate principle
Connection type
Plate connection
Standards
ISO 5599-1, ISO 1
Working pressure min./max.
See table
Control pressure min./max.
3—10 bar
Ambient temperature min./max.
0—50 Degree Celsius
Medium temperature min./max.
0—50 Degree Celsius
Medium
Compressed air
Max. particle size
5 um
Oil content of compressed air
0—0,01 mg/m3
Nominal flow Qn
1060 l/min
Protection class with connection
IP65
Compatibility index
15
Duty cycle
100 %
Switch-on time max.
18 ms
Switch-off time max.
40 ms
Version sensor
electronic PNP, with LED
Sensor connection
Plug, M8, 3-pin, with knurled screw
Operating voltage sensor DC min./max.
10—30 V DC
Voltage drop sensor U at Imax
? 2,5 V
Vibration resistance sensor
10 ?C 55 Hz, 1 mm
Shock resistance sensor
30 g / 11 ms
Cable length sensor
0,3 m
Protection class sensor acc. to DIN EN 61140
Class III
Mounting screw
M5 with hexagon socket
Weight
See table
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 Degree Celsius under ambient and medium temperature and may not exceed 3 Degree Celsius .
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS. Further information can be found in the ??Technical information?? document (available in the MediaCentre).
When the valve is not actuated, the sensor sends a signal through pin 4 of the sensor connection.
When the valve is actuated, the sensor does not send a signal through pin 4 of the sensor connection.
The valve with position detection is possible to be used in categories 3 and 4 according to ISO 13849 in order to reach a Performance Level (PL) of the control system up to PL = e.
On its own, the valve with position detection is not a safety component and is not a complete safety solution. It is designed to increase the diagnostic coverage (DC) of the control system.
For use in categories 3 to 4, additional requirements of DIN EN ISO 13849-1:2008-12 (e.g. CCF, DC, PLr, software, systematic errors) are taken into consideration by the user.
Housing
Polyamide Aluminum
Seals
Acrylonitrile butadiene rubber