描述
Standardization
ISO 5599-1
Frame size
ISO 3
Switching principle
5/2
Version
Poppet valve
Housing
Aluminum
Sealing material
Acrylonitrile butadiene rubber
Protection class
IP65
Port size
EN 175301-803, form A
Type
Plug
Nominal flow Qn
4300 l/min
Operational voltage AC at 50 Hz
110 V
Operational voltage AC at 60 Hz
110 V
DC operating voltage
110 V
Activation
Electrically
Version
Poppet valve
Activation
Electrically
Pilot
Internal
Sealing principle
Soft sealing
Blocking principle
Single base plate principle
Standards
ISO 5599-1, ISO 3
Working pressure min./max.
3,5—9 bar
Control pressure min./max.
3,5—9 bar
Ambient temperature min./max.
10—120 Degree Celsius
Medium temperature min./max.
10—120 Degree Celsius
Medium
Compressed air
Max. particle size
50 um
Oil content of compressed air
0—5 mg/m3
Nominal flow Qn
4300 l/min
Protection class with connection
IP65
Duty cycle
100 %
Typ. switch-on time
50 ms
Typ. switch-off time
80 ms
Mounting screw tightening torque
11 Nm
Weight
1,73 kg
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 Degree Celsius under ambient and medium temperature and may not exceed 3 Degree Celsius .
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS. Further information can be found in the ??Technical information?? document (available in the MediaCentre).
Max. ambient temperature: +180 Degree Celsius at 1 hour continuous operation and up to +200 Degree Celsius at 15 hours standby operation
At an ambient temperature of over 120 Degree Celsius , the duty cycle is reduced by 50%.
Scope of delivery: incl. valve plug connector and pilot valve
Material
Housing
Aluminum
Seals
Acrylonitrile butadiene rubber




评价