描述
Version
Poppet valve
Housing
Polyamide
Sealing material
Acrylonitrile butadiene rubber
Qn 1?2
3500 l/min
Qn 2?3
3200 l/min
Nominal flow Qn
3500 l/min
Compressed air connection input
G 1/2
Compressed air connection output
G 1/2
Version
Poppet valve, Can be assembled into blocks
Pilot
Internal
Sealing principle
Soft sealing
Working pressure min./max.
0—16 bar
Control pressure min./max.
2,5—16 bar
Ambient temperature min./max.
-10—50 Degree Celsius
Medium temperature min./max.
-10—50 Degree Celsius
Medium
Compressed air Neutral gases
Max. particle size
40 um
Weight
0,924 kg
The delivered product varies from that in the illustration. See the drawing for an exact description.
The pressure dew point must be at least 15 Degree Celsius under ambient and medium temperature and may not exceed 3 Degree Celsius .
The filling valve builds up pressure slowly in the pneumatic systems, i.e. prevents a sudden pressure build-up during a recommissioning after a mains pressure failure or avoids emergency OFF switching. This allows dangerous abrupt cylinder motions to be avoided.
Do not position filling valves or filling units upstream of open consumers, such as nozzles, air barriers, air curtains, since these may prevent through connection of components.
Suitable for use in Ex zones 1, 2, 21, 22.
A change in the flow direction (from air supply on the left to air supply on the right) occurs by rotating installation by 180?? about the vertical axis. Please see the operating instructions for further details.
Material
Housing
Polyamide
Front plate
Acrylonitrile butadiene styrene
Seals
Acrylonitrile butadiene rubber
Threaded bushing
Die cast zinc




评价
目前还没有评价