描述
Actuating control
single solenoid
Return type
With spring return
Switching principle
3/2
Version
Spool valve, positive overlapping
Housing
Aluminum,Polyamide fiber-glass reinforced
Sealing material
Acrylonitrile butadiene rubber,Polyurethane
Connector standard
EN 175301-803:2006
Protection class
IP65
Number of wires
3-pin
Port size
EN 175301-803, form A
Type
Plug
Qn 1?2
4000 l/min
Qn 2?3
4000 l/min
Nominal flow Qn
4000 l/min
Compressed air connection input
M22x1,5
Compressed air connection output
M22x1,5
DC operating voltage
24 V
Activation
Electrically
Temperature resistance
-25 Degree Celsius cold-resistant
Version
Spool valve, positive overlapping
Activation
Electrically
Pilot
Internal
Sealing principle
Soft sealing
Working pressure min./max.
2—16 bar
Control pressure min./max.
2—16 bar
Ambient temperature min./max.
-25—50 Degree Celsius
Medium temperature min./max.
-25—50 Degree Celsius
Medium
Compressed air
Max. particle size
50 um
Oil content of compressed air
0—1 mg/m3
Nominal flow Qn
4000 l/min
Nominal flow 1 ? 2
4000 l/min
Nominal flow 2 ? 3
4000 l/min
Pilot control exhaust
with directional pilot air exhaust
Connector standard
EN 175301-803:2006
Protection class with connection
IP65
Reverse polarity protection
Protected against polarity reversal
Compatibility index
14
Duty cycle
100 %
Typ. switch-on time
34 ms
Typ. switch-off time
90 ms
Weight
0,85 kg
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 Degree Celsius under ambient and medium temperature and may not exceed 3 Degree Celsius .
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS. Further information can be found in the ??Technical information?? document (available in the MediaCentre).
ATEX optional: ATEX version can be produced by combining the basic valve without coil with an ATEX coil. ATEX ID: see ATEX coils catalog page.
option valve: The input and output compressed air connections can be exchanged.The valve can thereby be used in the NC or NO operating mode.
*Note: Basic valves feature a maximum working pressure of 16 bar. When combined with standard CNOMO pilots, the maximum working pressure is 10 bar.
Material
Housing
Aluminum Polyamide fiber-glass reinforced
Seals
Acrylonitrile butadiene rubber Polyurethane