描述
Version
Poppet valve
Housing
Polyamide
Sealing material
Acrylonitrile butadiene rubber,Polyurethane
Protection class
IP65
Port size
ISO 15217, form C
Type
Plug
Nominal flow Qn
850 l/min
Compressed air connection input
mm8*1
Compressed air connection output
mm8*1
Operational voltage AC at 50 Hz
24 V
Operational voltage AC at 60 Hz
24 V
Activation
Electrically
Version
Poppet valve
Activation
Electrically
Pilot
External
Sealing principle
Soft sealing
Working pressure min./max.
0,5—8 bar
Control pressure min./max.
2—8 bar
Ambient temperature min./max.
-15—50 Degree Celsius
Medium temperature min./max.
-15—50 Degree Celsius
Medium
Compressed air
Max. particle size
5 um
Oil content of compressed air
0—1 mg/m3
Nominal flow Qn
See table
Protection class with connection
IP65
Reverse polarity protection
Protected against polarity reversal
Duty cycle
100 %
Typ. switch-on time
18 ms
Typ. switch-off time
16 ms
Weight
0,093 kg
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
The pressure dew point must be at least 15 Degree Celsius under ambient and medium temperature and may not exceed 3 Degree Celsius .
The oil content of compressed air must remain constant during the life cycle.
Use only the approved oils from AVENTICS. Further information can be found in the ??Technical information?? document (available in the MediaCentre).
At an ambient temperature of 40 Degree Celsius the max. working pressure is 10 bar .
Versions with voltage of less than 50 V DC do not have a protective ground.
The control pressure must be at least as high as the working pressure.
Material
Housing
Polyamide
Seals
Acrylonitrile butadiene rubber Polyurethane




评价
目前还没有评价